k8ik-stm/Misc/Temp-Monitor/temperature_monitor.py
Rahix 12753d93fb temp: Slow down reports
Only send a new report every 200ms to hopefully mitigate the serial port
glitches.
2025-08-24 03:21:46 +02:00

47 lines
1,016 B
Python

import math
import time
from cs1237 import CS1237
from machine import Pin
clock = Pin(2)
data = Pin(4)
ADC_RATE = 40
cs1237 = CS1237(clock, data)
cs1237.config(gain=1, rate=ADC_RATE)
cs1237.get_config()
THERMISTOR_BETA = 3950.0
THERMISTOR_R25 = 10e3
THERMISTOR_RINF = THERMISTOR_R25 * math.exp(-THERMISTOR_BETA / 298.15)
# Filter constant in seconds
FILTER_RC = 1
FILTER_A = 1 / ADC_RATE / (FILTER_RC / 1 / ADC_RATE)
temperature_filtered = 25
last_report = time.ticks_ms()
while True:
raw_value = cs1237.read()
value = float(raw_value) / (2**24 - 1)
if value > 0.9999:
value = 0
else:
value = 10e3 * 1 / (1 / value - 1)
temperature = THERMISTOR_BETA / math.log(value / THERMISTOR_RINF) - 273.15
temperature_filtered = (
temperature_filtered * (1 - FILTER_A) + temperature * FILTER_A
)
now = time.ticks_ms()
elapsed = now - last_report
if elapsed >= 200 or elapsed < 0:
print(f"{temperature_filtered:.6f}")
last_report = now