Temperature Measurement & MODBUS Integration #17
|
@ -40,28 +40,27 @@ func (d *daemon) modbusConnect() error {
|
||||||
// The first one (slave 1) is a temperature/humidity sensor.
|
// The first one (slave 1) is a temperature/humidity sensor.
|
||||||
// The second one (slave 2) is a PTA8D08 transmitter
|
// The second one (slave 2) is a PTA8D08 transmitter
|
||||||
func (d *daemon) modbusUpdate() error {
|
func (d *daemon) modbusUpdate() error {
|
||||||
d.mu.Lock()
|
|
||||||
defer d.mu.Unlock()
|
|
||||||
|
|
||||||
var err error
|
var err error
|
||||||
var registers []uint16 // temperature, humidity
|
|
||||||
|
|
||||||
// Switch to slave 1
|
// Switch to slave 1 (BTA1)
|
||||||
d.modbusClient.SetUnitId(1)
|
d.modbusClient.SetUnitId(1)
|
||||||
|
|
||||||
// Read temperature and humidity
|
// Read temperature and humidity
|
||||||
registers, err = d.modbusClient.ReadRegisters(1, 2, modbus.INPUT_REGISTER)
|
var registersBTA1 []uint16 // temperature, humidity
|
||||||
|
registersBTA1, err = d.modbusClient.ReadRegisters(1, 2, modbus.INPUT_REGISTER)
|
||||||
if err != nil {
|
if err != nil {
|
||||||
return err
|
return err
|
||||||
}
|
}
|
||||||
|
|
||||||
if len(registers) != 2 {
|
if len(registersBTA1) != 2 {
|
||||||
msg := fmt.Sprintf("Expected two registers from modbus slave 1, but got %d", len(registers))
|
msg := fmt.Sprintf("Expected two registers from modbus slave 1, but got %d", len(registersBTA1))
|
||||||
return errors.New(msg)
|
return errors.New(msg)
|
||||||
}
|
}
|
||||||
|
|
||||||
d.daemonState.tempSEM = modbusValuesToFloat(registers[0])
|
d.mu.Lock()
|
||||||
d.daemonState.humiditySEM = modbusValuesToFloat(registers[1])
|
d.daemonState.tempSEM = modbusValuesToFloat(registersBTA1[0])
|
||||||
|
d.daemonState.humiditySEM = modbusValuesToFloat(registersBTA1[1])
|
||||||
|
d.mu.Unlock()
|
||||||
|
|
||||||
// Switch to slave 2 (KEC2)
|
// Switch to slave 2 (KEC2)
|
||||||
d.modbusClient.SetUnitId(2)
|
d.modbusClient.SetUnitId(2)
|
||||||
|
@ -70,18 +69,21 @@ func (d *daemon) modbusUpdate() error {
|
||||||
// Channel 0: Cable -WGA6, Sensor "dp bottom"
|
// Channel 0: Cable -WGA6, Sensor "dp bottom"
|
||||||
// Channel 1: Cable -WGA8, Sensor "dp inlet"
|
// Channel 1: Cable -WGA8, Sensor "dp inlet"
|
||||||
// Channel 2: Cable WGA7, Sensor "dp top"
|
// Channel 2: Cable WGA7, Sensor "dp top"
|
||||||
registers, err = d.modbusClient.ReadRegisters(0, 3, modbus.HOLDING_REGISTER)
|
var registersKEC2 []uint16 // temperatures dp
|
||||||
|
registersKEC2, err = d.modbusClient.ReadRegisters(0, 3, modbus.HOLDING_REGISTER)
|
||||||
if err != nil {
|
if err != nil {
|
||||||
return err
|
return err
|
||||||
}
|
}
|
||||||
|
|
||||||
if len(registers) != 3 {
|
if len(registersKEC2) != 3 {
|
||||||
return fmt.Errorf("expected three registers from modbus slave 2, but got %d", len(registers))
|
return fmt.Errorf("expected three registers from modbus slave 2, but got %d", len(registersKEC2))
|
||||||
}
|
}
|
||||||
|
|
||||||
d.daemonState.tempDPBottom = modbusValuesToFloat(registers[0])
|
d.mu.Lock()
|
||||||
d.daemonState.tempDPInlet = modbusValuesToFloat(registers[1])
|
d.daemonState.tempDPBottom = modbusValuesToFloat(registersKEC2[0])
|
||||||
d.daemonState.tempDPTop = modbusValuesToFloat(registers[2])
|
d.daemonState.tempDPInlet = modbusValuesToFloat(registersKEC2[1])
|
||||||
|
d.daemonState.tempDPTop = modbusValuesToFloat(registersKEC2[2])
|
||||||
|
d.mu.Unlock()
|
||||||
|
|
||||||
// Switch to slave 3 (KEC1)
|
// Switch to slave 3 (KEC1)
|
||||||
d.modbusClient.SetUnitId(3)
|
d.modbusClient.SetUnitId(3)
|
||||||
|
@ -106,7 +108,7 @@ func (d *daemon) modbusUpdate() error {
|
||||||
|
|
||||||
// KFA1-KFA8
|
// KFA1-KFA8
|
||||||
var relayState [8]bool
|
var relayState [8]bool
|
||||||
|
d.mu.Lock()
|
||||||
// -KFA1 Roughing Pump (normally closed contact)
|
// -KFA1 Roughing Pump (normally closed contact)
|
||||||
relayState[0] = !d.daemonState.rpOn
|
relayState[0] = !d.daemonState.rpOn
|
||||||
// -KFA2 Diffusion Pump
|
// -KFA2 Diffusion Pump
|
||||||
|
@ -119,23 +121,24 @@ func (d *daemon) modbusUpdate() error {
|
||||||
relayState[5] = !d.aboveRough.output
|
relayState[5] = !d.aboveRough.output
|
||||||
// -KFA7 Fake-Pirani High (normally closed contact)
|
// -KFA7 Fake-Pirani High (normally closed contact)
|
||||||
relayState[6] = !d.aboveHigh.output
|
relayState[6] = !d.aboveHigh.output
|
||||||
|
d.mu.Unlock()
|
||||||
|
|
||||||
// The KEC1 module uses a non-standard MODBUS interface
|
// The KEC1 module uses a non-standard MODBUS interface
|
||||||
// instead of coils
|
// instead of coils
|
||||||
// 0x0100 is the open command
|
// 0x0100 is the open command
|
||||||
// 0x0200 is the close command
|
// 0x0200 is the close command
|
||||||
// We write 8 words (16-bit) to address 0x01 to update the relays
|
// We write 8 words (16-bit) to address 0x01 to update the relays
|
||||||
var registerValues [8]uint16
|
var registerValuesKEC1 [8]uint16
|
||||||
// Convert the boolean values to the commands
|
// Convert the boolean values to the commands
|
||||||
for idx, state := range relayState {
|
for idx, state := range relayState {
|
||||||
if state {
|
if state {
|
||||||
registerValues[idx] = 0x0100
|
registerValuesKEC1[idx] = 0x0100
|
||||||
} else {
|
} else {
|
||||||
registerValues[idx] = 0x0200
|
registerValuesKEC1[idx] = 0x0200
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
err = d.modbusClient.WriteRegisters(0x01, registerValues[:])
|
err = d.modbusClient.WriteRegisters(0x01, registerValuesKEC1[:])
|
||||||
if err != nil {
|
if err != nil {
|
||||||
return err
|
return err
|
||||||
}
|
}
|
||||||
|
|