Temperature Measurement & MODBUS Integration #17

Merged
rahix merged 13 commits from more-temps into main 2024-11-10 06:58:09 +00:00
Showing only changes of commit 6f93b96c39 - Show all commits

View file

@ -2,11 +2,10 @@ package main
import (
"context"
"errors"
"fmt"
"time"
"github.com/simonvetter/modbus"
"k8s.io/klog"
)
func modbusValuesToFloat(v uint16) float32 {
@ -39,7 +38,7 @@ func (d *daemon) modbusConnect() error {
// There are currently two devices connected to the modbus.
// The first one (slave 1) is a temperature/humidity sensor.
// The second one (slave 2) is a PTA8D08 transmitter
func (d *daemon) modbusUpdate() error {
func (d *daemon) modbusUpdate() {
var err error
// Switch to slave 1 (BTA1)
@ -49,18 +48,15 @@ func (d *daemon) modbusUpdate() error {
var registersBTA1 []uint16 // temperature, humidity
registersBTA1, err = d.modbusClient.ReadRegisters(1, 2, modbus.INPUT_REGISTER)
if err != nil {
return err
}
if len(registersBTA1) != 2 {
msg := fmt.Sprintf("Expected two registers from modbus slave 1, but got %d", len(registersBTA1))
return errors.New(msg)
}
klog.Warningf("error while reading registers from BTA1 %v", err)
} else if len(registersBTA1) != 2 {
klog.Warningf("expected two registers from modbus slave 1, but got %d", len(registersBTA1))
} else {
d.mu.Lock()
d.daemonState.tempSEM = modbusValuesToFloat(registersBTA1[0])
d.daemonState.humiditySEM = modbusValuesToFloat(registersBTA1[1])
d.mu.Unlock()
}
// Switch to slave 2 (KEC2)
d.modbusClient.SetUnitId(2)
@ -72,18 +68,16 @@ func (d *daemon) modbusUpdate() error {
var registersKEC2 []uint16 // temperatures dp
registersKEC2, err = d.modbusClient.ReadRegisters(0, 3, modbus.HOLDING_REGISTER)
if err != nil {
return err
}
if len(registersKEC2) != 3 {
return fmt.Errorf("expected three registers from modbus slave 2, but got %d", len(registersKEC2))
}
klog.Warningf("error while reading registers from KEC2 %v", err)
} else if len(registersKEC2) != 3 {
klog.Warningf("expected three registers from modbus slave 2, but got %d", len(registersKEC2))
} else {
d.mu.Lock()
d.daemonState.tempDPBottom = modbusValuesToFloat(registersKEC2[0])
d.daemonState.tempDPInlet = modbusValuesToFloat(registersKEC2[1])
d.daemonState.tempDPTop = modbusValuesToFloat(registersKEC2[2])
d.mu.Unlock()
}
// Switch to slave 3 (KEC1)
d.modbusClient.SetUnitId(3)
@ -94,8 +88,8 @@ func (d *daemon) modbusUpdate() error {
digitalInputRegisters, err = d.modbusClient.ReadRegisters(0x81, 8, modbus.HOLDING_REGISTER)
if err != nil {
return err
}
klog.Warningf("error while reading digital inputs from KEC1 %v", err)
} else {
// Convert MODBUS words into bools
for idx, value := range digitalInputRegisters {
if value != 0 {
@ -105,6 +99,7 @@ func (d *daemon) modbusUpdate() error {
}
}
// TODO: Input mapping goes here
}
// KFA1-KFA8
var relayState [8]bool
@ -140,10 +135,8 @@ func (d *daemon) modbusUpdate() error {
err = d.modbusClient.WriteRegisters(0x01, registerValuesKEC1[:])
if err != nil {
return err
klog.Warningf("error while updating registers %v", err)
}
return nil
}
// Call modbusUpdate every 100 milliseconds